INTERNATIONAL JOURNAL OF NOVEL RESEARCH AND DEVELOPMENT International Peer Reviewed & Refereed Journals, Open Access Journal ISSN Approved Journal No: 2456-4184 | Impact factor: 8.76 | ESTD Year: 2016
Scholarly open access journals, Peer-reviewed, and Refereed Journals, Impact factor 8.76 (Calculate by google scholar and Semantic Scholar | AI-Powered Research Tool) , Multidisciplinary, Monthly, Indexing in all major database & Metadata, Citation Generator, Digital Object Identifier(DOI)
The design of capillary tube plays a very important role in the performance of a vapor compression refrigeration system. Optimized design is possible through theoretical calculations, however may fail due to the reason that the uncertainties in the formulation of pressure drop inside the capillary tubes. Hence experimental investigations are the best in terms of optimization of certain design parameters. Components of the vapor compression refrigeration system never work in isolation; change in performance of one component affect the performance of the other components and in turn overall performance of the system. Performance of the system also depends on the type, quantity of the refrigerant charged. In the present work, an attempt is made to optimize Length of capillary tube for refrigeration unit of capacity 30lts; with R-134a as refrigerant and hermetic sealed compressor of capacity 0.14H.P.and this study examined the effects of lengths capillary tubes on the performance of a vapor compression refrigeration system. It is found that 4.5feet Length of capillary tube gave a better performance. Both inlet and outlet pressure and temperature of the test section (capillary tube) were measured and used to estimate the coefficient of performance (COP) of the system the parameters stated above can be further optimized in order to enhance the performance of the refrigeration system.
Keywords:
Vapor compression Refrigeration System, capillary tube, refrigerants, coefficient of performance.
Cite Article:
"EXPERIMENTAL ANALYSIS ON THE PERFORMANCE OF VAPOUR COMPRESSION REFREGERATION SYSTEM USING DIFFERENT REFRIGERENTS - A REVIEW", International Journal of Novel Research and Development (www.ijnrd.org), ISSN:2456-4184, Vol.8, Issue 8, page no.c505-c509, August-2023, Available :http://www.ijnrd.org/papers/IJNRD2308268.pdf
Downloads:
000118752
ISSN:
2456-4184 | IMPACT FACTOR: 8.76 Calculated By Google Scholar| ESTD YEAR: 2016
An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 8.76 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator
Facebook Twitter Instagram LinkedIn